Kiln Control Box Wiring

Wiring diagram, step-by-step instructions and a connection checklist for the Fuji PXR3 and relay control box on Glass Hive lampworking kilns.

⬇ Download the printable PDF (with checklist)

Unplug before wiring. Never work in the control box with the kiln plugged in. Questions? Call 541-961-6978 before powering up.

Wiring diagram

Wiring diagram for a Glass Hive kiln control box: Fuji PXR3 controller, toggle switch, relay, Type K thermocouple, element and power cord

Blue = control box wire. Brown = element lead. A dot means the wires are joined at that point. Tap the diagram to view it full size.

Wiring steps

  1. Unplug the kiln and open the control box.
  2. Thermocouple: RED to Fuji 2, YELLOW to Fuji 3. Polarity matters: reversed leads make the reading go the wrong way.
  3. Jumper: connect Fuji 5 to Fuji 8.
  4. Controller to switch: Fuji 8 to switch bottom left, Fuji 9 to switch bottom right.
  5. Controller to relay: Fuji 4 to the relay's top right terminal ("Fuji 4"). Switch bottom right to the relay's bottom right terminal ("switch").
  6. Power cord: WHITE to switch top right and relay top middle ("line in"). BLACK to switch top left and relay bottom middle ("line in"). GREEN to the box ground.
  7. Element: one lead to relay top left, the other to relay bottom left (both marked "element").
  8. Leave Fuji 1, 6 and 7 empty.
  9. Tug each wire to make sure it's tight, then tick it off in the checklist.

Connection checklist

From To
Thermocouple RED Fuji 2
Thermocouple YELLOW Fuji 3
Jumper Fuji 5 to Fuji 8
Fuji 4 Relay top right ("Fuji 4")
Fuji 8 Switch bottom left
Fuji 9 Switch bottom right
Switch bottom right Relay bottom right ("switch")
Cord WHITE Switch top right + Relay top middle ("line in")
Cord BLACK Switch top left + Relay bottom middle ("line in")
Cord GREEN Ground (box)
Element lead 1 Relay top left ("element")
Element lead 2 Relay bottom left ("element")
Fuji 1, 6, 7 Not used

The printable PDF has tick boxes for each connection.

First power-up

  • Check every connection against the table before plugging in.
  • Plug in and flip the toggle switch on. The Fuji should light up and show about room temperature.
  • If the temperature reading goes down as the kiln heats, the thermocouple leads are swapped: unplug and swap RED and YELLOW.
  • Run an autotune before the first firing (see the Fuji PXR3 Controller Guide).